Exam technique and practice

Worked example

A 6-mark explanation

Question: Explain how a transformer can produce a lower alternating p.d. from the 230 V mains, and why it will not work from a battery. (6 marks)

Show solution

Model answer (top level): A transformer has a primary coil and a secondary coil wound on the same soft iron core; the coils are not connected to each other electrically. The alternating current from the mains in the primary coil produces a magnetic field that is constantly changing in size and direction. The iron core is easily magnetised and demagnetised, so it carries this changing magnetic field through the secondary coil. Because the magnetic field through the secondary coil is changing, an alternating potential difference is induced across it. The size of the output depends on the turns ratio: VpVs=NpNs\frac{V_p}{V_s} = \frac{N_p}{N_s}, so to produce a lower p.d. the secondary coil must have fewer turns than the primary, making it a step-down transformer. A battery supplies direct current, which is steady, so the magnetic field in the core would be constant once the current was switched on. A constant field does not induce any p.d., so the transformer would produce no output.

Why it reaches the top level: it gives the structure, the full chain from alternating current to induced p.d., links the turns to the output with the equation, and explains clearly why d.c. fails.

Exam technique

  • (Higher tier) Both transformer equations are given, but choose the right one: the turns ratio for p.d.s and turns; the power equation for currents.
  • (Higher tier) Keep primary on top on both sides: VpVs=NpNs\frac{V_p}{V_s} = \frac{N_p}{N_s}.
  • For "why high voltage?", write the full chain: high voltage → low current → less heating (P=I2RP = I^2R) → less energy wasted → more efficient.
  • For "how does a transformer work?", use the words alternating current, changing magnetic field, iron core and induced.
  • Say where each type is used: step-up at the power station, step-down near homes.

Common mistakes

  • Saying transformers work with d.c. Fix: they need a changing field, so only a.c. works.
  • Saying a step-up transformer increases the power. Fix: power in = power out at best; stepping up the p.d. steps down the current.
  • Saying high voltage reduces the resistance of the cables. Fix: the resistance is unchanged; the current is smaller, so less energy is wasted.
  • Turning the turns ratio upside down on one side of the equation.
  • Saying the coils are joined by wires. Fix: they are linked only by the changing magnetic field in the core.

Check yourself

  1. What is the core of a transformer made of, and why?
  2. Why won't a transformer work with direct current?
  3. A transformer has 100 turns on the primary and 400 on the secondary. Is it step-up or step-down?
  4. (Higher tier) The transformer in question 3 has 12 V across the primary. What is the secondary p.d.?
  5. (Higher tier) A 100% efficient transformer takes in 240 W. What is its output power?
  6. Why does the National Grid transmit at a very high voltage?
  7. Where are step-up and step-down transformers used in the National Grid?
  8. (Higher tier) A transformer steps 230 V down to 11.5 V. Its secondary has 60 turns. How many turns are on the primary?
  9. (Higher tier) A 100% efficient transformer steps 11 kV up to 132 kV. The secondary current is 50 A. Find the primary current.
  10. Power of 2.0 MW is sent through cables of resistance 2.0 Ω at 20 kV. Find the power wasted, and what it would be at 40 kV.
Show answers
  1. Soft iron, because it is easily magnetised and demagnetised, so it carries the changing field.
  2. The magnetic field would not change, so no p.d. would be induced in the secondary.
  3. Step-up.
  4. Vs=12×400100=48V_s = 12 \times \frac{400}{100} = 48 V.
  5. 240 W.
  6. A high voltage means a small current for the same power, so much less energy is wasted heating the cables.
  7. Step-up at the power station; step-down at substations near where the electricity is used.
  8. Np=60×23011.5=1200N_p = 60 \times \frac{230}{11.5} = 1200 turns.
  9. Ip=132 000×5011 000=600I_p = \frac{132\,000 \times 50}{11\,000} = 600 A.
  10. I=2.0×10620 000=100I = \frac{2.0 \times 10^{6}}{20\,000} = 100 A, so P=1002×2.0=20 000P = 100^{2} \times 2.0 = 20\,000 W (20 kW); at 40 kV, I=50I = 50 A, so P=502×2.0=5000P = 50^{2} \times 2.0 = 5000 W (5 kW), a quarter.