Skip to main content
Examonaut

Topic 4.7.3 · Lesson 2 of 4

Microphones and transformers

Microphones

A moving-coil microphone is a loudspeaker working in reverse. It uses the generator effect to turn the pressure variations of sound into variations in current.

diaphragmmagnetcoilvarying current to amplifiersoundvibrates
  1. Sound waves (pressure variations in the air) hit a thin, light diaphragm, making it vibrate.
  2. A coil attached to the diaphragm moves back and forth with it, in the field of a permanent magnet.
  3. The coil moves relative to the magnetic field, so a p.d. is induced across it, and a current flows in the circuit.
  4. The current varies in the same pattern as the sound wave: a louder sound gives bigger vibrations and a bigger current; a higher-pitched sound gives faster vibrations and a higher-frequency current.
  5. The varying current is passed to an amplifier (and then perhaps to a loudspeaker).

Transformers

A transformer changes the size of an alternating potential difference. It has a primary coil and a secondary coil wound on the same iron core. The two coils are not electrically connected.

iron coreprimary coilsecondary coila.c. input: Vp, np turnsoutput: Vs, ns turns

How it works.

  1. Step 1: An alternating current in the primary coil produces a changing magnetic field (it grows, shrinks and reverses many times each second).
  2. Step 2: The iron core is easily magnetised, so it carries this changing field through the secondary coil.
  3. Step 3: The secondary coil is in a changing magnetic field, so an alternating p.d. is induced across it. If it is part of a complete circuit, an alternating current flows.

A transformer will not work on d.c.: a steady current gives a steady field, which induces nothing (except a brief flick when it is switched on or off).

The turns ratio equation. The p.d.s are in the same ratio as the numbers of turns:

VpVs=npns\frac{V_p}{V_s} = \frac{n_p}{n_s}
  • VpV_p is the p.d. across the primary coil, in volts (V); VsV_s is the p.d. across the secondary coil, in volts (V);
  • npn_p and nsn_s are the numbers of turns on the primary and secondary coils (no unit).

This equation is on the AQA Physics equation sheet.

  • A step-up transformer has more turns on the secondary, so Vs>VpV_s > V_p.
  • A step-down transformer has fewer turns on the secondary, so Vs<VpV_s < V_p.

The power equation. If a transformer is 100% efficient (good transformers are about 99% efficient), the power output equals the power input. Since electrical power is P=VIP = VI:

Vs×Is=Vp×IpV_s \times I_s = V_p \times I_p
  • IpI_p and IsI_s are the currents in the primary and secondary coils, in amperes (A).

This equation is also on the equation sheet. Vs×IsV_s \times I_s is the power output and Vp×IpV_p \times I_p is the power input, in watts. It means that if a transformer steps the p.d. up, it steps the current down by the same factor, and the other way round. A transformer does not give you free energy.

Worked example

The turns ratio

A transformer has 200 turns on its primary coil and 4000 turns on its secondary coil. The primary is connected to a 12 V a.c. supply. Calculate the output p.d.

Show solution
  1. Write the equation: VpVs=npns\frac{V_p}{V_s} = \frac{n_p}{n_s}.
  2. Substitute: 12Vs=2004000=0.05\frac{12}{V_s} = \frac{200}{4000} = 0.05.
  3. Rearrange: Vs=120.05=240V_s = \frac{12}{0.05} = 240 V.
  4. It is a step-up transformer (more turns on the secondary), so a bigger output makes sense.

A quicker route: the secondary has 4000200=20\frac{4000}{200} = 20 times as many turns, so the p.d. is 20 times bigger: 12×20=24012 \times 20 = 240 V.

Worked example

Finding the number of turns

A phone charger contains a transformer that steps 230 V down to 5.0 V. The primary coil has 1840 turns. How many turns are on the secondary?

Show solution
  1. Rearrange: ns=np×VsVpn_s = n_p \times \frac{V_s}{V_p}.
  2. ns=1840×5.0230=1840×0.02174=40n_s = 1840 \times \frac{5.0}{230} = 1840 \times 0.02174 = 40 turns.

Worked example

Current drawn from the supply

A 100% efficient transformer steps 230 V down to 12 V to run a 36 W lamp. Calculate (a) the current in the lamp and (b) the current drawn from the 230 V supply.

Show solution
  1. (a) Output power =VsIs= V_s I_s, so Is=3612=3.0I_s = \frac{36}{12} = 3.0 A.
  2. (b) Input power = output power =36= 36 W, so VpIp=36V_p I_p = 36.
  3. Ip=36230=0.157I_p = \frac{36}{230} = 0.157 A, about 0.16 A.
  4. Check: the p.d. is stepped down by a factor of 23012=19.2\frac{230}{12} = 19.2, so the current is stepped up by the same factor: 0.157×19.2=3.00.157 \times 19.2 = 3.0 A. ✓

Worked example

Transformer chaintop grade

A step-down transformer at a substation has a turns ratio np:nsn_p : n_s of 50 : 1. It is fed at 11 000 V and supplies a current of 400 A to a town. Assuming it is 100% efficient, calculate the output p.d. and the current in its primary coil.

Show solution
  1. Vs=Vp×nsnp=11 000×150=220V_s = V_p \times \frac{n_s}{n_p} = 11\,000 \times \frac{1}{50} = 220 V.
  2. Output power =VsIs=220×400=88 000= V_s I_s = 220 \times 400 = 88\,000 W.
  3. Ip=88 00011 000=8.0I_p = \frac{88\,000}{11\,000} = 8.0 A (the current is stepped down by the same factor of 50).

Practise this topic