Topic 4.7.3 · Lesson 4 of 4
Exam technique and practice
Worked example
A 6-mark explanation
"Explain how a transformer can be used to step up an alternating potential difference, and explain why step-up transformers are used in the National Grid." (6 marks)
Show solutionHide solution
AQA marks this by levels. A top-level answer (5–6 marks) explains the full induction chain (alternating current, changing field, iron core, induced p.d.), links step-up to more turns on the secondary, and explains the energy saving using the lower current. A middle-level answer (3–4 marks) gives part of each. A low-level answer (1–2 marks) makes isolated statements such as "it makes the voltage bigger".
Model answer: "The transformer has a primary coil and a secondary coil wound on an iron core. An alternating current in the primary coil produces a magnetic field that keeps changing in size and direction. The iron core is easily magnetised, so it carries this changing field through the secondary coil. A changing magnetic field through the secondary coil induces an alternating potential difference across it. To step up the p.d., the secondary coil has more turns than the primary, because the ratio of the p.d.s equals the ratio of the turns. In the National Grid, step-up transformers raise the p.d. before transmission. For the same power, a higher p.d. means a smaller current, since power equals p.d. times current. A smaller current means much less energy is wasted heating the cables, because the power wasted depends on the current squared, so the energy is transmitted more efficiently."
What lifts it to the top level: every link in the chain (a.c. → changing field → core → induced p.d.), the turns explanation, and the reason for high p.d. (lower current, less heating) all present and in a logical order.
Exam technique
- Use the word "induced": "a potential difference is induced", not "electricity is made".
- Stress that a change or relative movement is needed; a stationary magnet induces nothing.
- For alternators, name the slip rings; for dynamos, the split-ring commutator. Don't mix them up.
- On V–t graphs, read the period from one complete cycle, then . Faster rotation: higher peak and higher frequency.
- In transformer calculations, check your answer makes sense: more turns on the secondary means a bigger output p.d. and a smaller output current.
- For National Grid questions, always say: higher p.d. → lower current → less energy lost heating the cables → more efficient.
Common mistakes
- Saying a transformer works on d.c. Fix: it needs a.c., so the magnetic field keeps changing.
- Saying current flows through the iron core from one coil to the other. Fix: the coils are not connected; the core carries the changing magnetic field.
- Saying a step-up transformer increases the power. Fix: power out equals power in (at best); if the p.d. goes up, the current goes down.
- Saying faster rotation of an alternator only increases the frequency. Fix: it increases both the frequency and the peak p.d.
- Saying the National Grid uses high p.d. "to make it travel faster". Fix: high p.d. means low current, so less energy is wasted heating the cables.
- Writing the turns ratio upside down. Fix: primary over secondary on both sides: .
Check yourself
- State two ways of inducing a potential difference across a conductor.
- A magnet is held still inside a coil. Why is no current induced?
- Give three ways to increase the p.d. induced when a magnet is moved into a coil.
- When a north pole is pushed into a coil, what pole forms at the near end of the coil, and why?
- What is the difference between how an alternator and a dynamo are connected to the external circuit?
- An alternator's coil turns 25 times a second. What is the frequency and the period of the p.d.? What happens to the graph if it turns faster?
- Explain how a moving-coil microphone works.
- Why is the core of a transformer made of iron?
- A transformer has 500 turns on the primary and 25 turns on the secondary. The input is 230 V. Calculate the output p.d.
- A 100% efficient transformer gives an output of 4.0 A at 11.5 V from a 230 V supply. Calculate the current in the primary coil.
Show answersHide answers
- Move the conductor relative to a magnetic field; change the magnetic field around the conductor.
- There is no relative movement and no change in the field.
- Move the magnet faster; use a stronger magnet; use more turns on the coil (or add an iron core).
- A north pole, which repels the magnet, because the induced current's field opposes the change (the magnet's movement).
- An alternator uses slip rings, so the output is a.c.; a dynamo uses a split-ring commutator, which reverses the connections every half turn, so the output is d.c.
- 25 Hz, period 0.04 s; faster rotation gives a higher frequency (shorter period) and a bigger peak p.d.
- Sound waves make the diaphragm vibrate; the attached coil moves in the field of a permanent magnet, so a varying p.d. is induced, giving a current that varies in the same pattern as the sound.
- Iron is easily magnetised, so it carries the changing magnetic field from the primary to the secondary coil.
- V.
- Output power = 11.5 × 4.0 = 46 W; A.
Practise this topic
Both are part of Premium.