Topic 5B · Lesson 1 of 5
Carrying out an accurate titration
Why titrate?
In the acids lesson you neutralised an acid by adding powder until the pH changed. A titration does the same thing with far more precision. You measure an exact volume of one solution, then add the other from a burette until an indicator changes colour, reading the volume added to the nearest 0.05 cm³. The volume that exactly neutralises the first solution is called the titre. If you know the concentration of one solution, the titre lets you calculate the concentration of the other.
Core practical: an accurate titration
Aim: to find the volume of dilute hydrochloric acid that exactly neutralises 25.0 cm³ of sodium hydroxide solution. The apparatus is shown below.
- Rinse a pipette with a little of the sodium hydroxide solution, then use a pipette filler to measure exactly 25.0 cm³ into a clean conical flask. The bottom of the meniscus should sit exactly on the line.
- Add 2 or 3 drops of indicator: phenolphthalein (pink in alkali, colourless in acid) or methyl orange (yellow in alkali, red in acid). Stand the flask on a white tile so the colour change is easy to see.
- Rinse the burette with a little of the acid, then fill it using a small funnel, and remove the funnel. Run a little acid through the tap so the tip has no air bubble. Read the starting volume.
- Do a quick rough titration: add acid while swirling until the colour changes, to find roughly where the end point is.
- Repeat accurately with fresh alkali: add acid quickly to about 2 cm³ before the rough value, then drop by drop, swirling, until one drop makes the colour change permanently. This is the end point.
- Repeat until you have at least two concordant titres: results within 0.10 cm³ of each other.
Reading the burette correctly matters. Read it with your eye level with the bottom of the meniscus (the curved surface), and record to the nearest 0.05 cm³, as shown below.
Variables: the dependent variable is the titre. Control variables: the volume of alkali (fixed by the pipette), the concentrations of both solutions, and the type and amount of indicator.
Risks: sodium hydroxide solution is corrosive to the eyes even when dilute, and the acid is an irritant: wear eye protection. Fill the burette below eye level, standing it on the bench or lowering the clamp.
Sample results: a typical results table is shown below.
Processing the results:
- Each titre = final reading − initial reading.
- Ignore the rough titre: it was deliberately done quickly and overshoots.
- Choose the concordant titres: 23.75 and 23.65 cm³ (they differ by 0.10 cm³). Run 2 (23.45) is not concordant, so it is left out.
- Mean titre cm³.
- (Higher tier) This mean titre is then used to calculate the concentration, as in the worked examples below.
Errors and improvements:
- An air bubble in the burette tip, a funnel left in the burette, or reading the meniscus from above or below all give wrong volumes.
- Overshooting the end point gives a titre that is too large: add acid drop by drop near the end and swirl after each drop.
- Rinsing the pipette and burette with the solutions they will hold stops them being diluted by leftover water. (The conical flask can be wet: water there doesn't change the number of moles of alkali.)
- Repeating until results are concordant shows the result is reliable.
Practise this topic