Topic 5D · Lesson 2 of 3
Investigating surfaces and thermal radiation
Core practical: surfaces and thermal radiation
Aim: to investigate how the nature of a surface (matt black, shiny, white and so on) affects the amount of thermal energy it radiates or absorbs.
Apparatus (radiation): a Leslie cube (a hollow metal cube whose four vertical faces have different surfaces: matt black, shiny black, matt white and shiny silver), a kettle, a heatproof mat, an infrared detector (or a thermometer with a blackened bulb) and a ruler. The diagram below shows the set-up.
Method (radiation from a Leslie cube)
- Step 1: Stand the Leslie cube on a heatproof mat and fill it with very hot water from a kettle. Put the lid on.
- Step 2: Place the infrared detector exactly 5 cm from the centre of one face, pointing straight at it, and record the reading.
- Step 3: Turn the cube (or move the detector) and repeat at exactly the same distance for each face. Do this quickly, so the water temperature hardly changes.
- Step 4: Repeat the set of readings and calculate a mean for each face.
The matt black face gives the highest reading and the shiny silver face the lowest.
Alternative method (cooling cans): pour equal volumes of hot water at the same starting temperature into identical metal cans painted with different surfaces. Put lids on, and record the temperature of each every minute for 10 minutes. The faster a can cools, the better its surface is at emitting radiation.
Measuring absorption: stand two identical metal plates, one matt black and one shiny, at equal distances either side of a radiant heater. Fix a drawing pin to the back of each with a little wax. The pin falls first from the matt black plate, because it absorbs radiation faster and its wax melts first.
Variables: independent, the type of surface; dependent, the detector reading (or the temperature drop, or the time for the pin to fall); control, the starting temperature and volume of water, the distance from the detector or heater, the size and material of the can or plate, and the room temperature.
Risks: very hot water and the hot cube can scald, so handle carefully, keep the cube on a heatproof mat and mop up spills at once; radiant heaters get extremely hot, so don't touch them.
Processing results. For the cooling cans, plot temperature against time for each surface on the same axes, as in the graph below. A steeper curve shows faster cooling, so a better emitter. Calculate the average rate of cooling as temperature drop ÷ time.
Errors and improvements
- The cans also lose energy by conduction, convection and evaporation, not just radiation: use lids, and stand them on identical insulating mats.
- The detector must be at exactly the same distance from each face, because the intensity detected depends on distance.
- Reading several thermometers by hand at the same moment is difficult: use temperature probes and a data logger.
- Repeat the experiment and calculate means to make the results more reliable.
Worked example
Comparing rates of cooling
Two cans start at 80 °C. After 10 minutes the matt black can is at 62 °C and the shiny can is at 71 °C. Compare their average rates of cooling.
Show solutionHide solution
- Matt black: drop = °C, so rate = °C per minute.
- Shiny: drop = °C, so rate = °C per minute.
- The matt black can cools twice as fast, so its surface is the better emitter of radiation.
Practise this topic