Skip to main content
Examonaut

Topic 4.7.2 · Lesson 3 of 5

Calculating force with F = BIl (Higher tier)

The size of the force: F = BIlHigher tier

Three factors affect the size of the force on the wire:

  1. the magnetic flux density B (how strong the magnetic field is);
  2. the current I in the wire;
  3. the length l of wire inside the field.

For a wire at right angles to the field:

F=BIlF = BIl
  • F is the force in newtons (N);
  • B is the magnetic flux density in tesla (T);
  • I is the current in amperes (A);
  • l is the length of wire in the field in metres (m).

This equation is on the AQA Physics equation sheet, but you must know what each symbol means and its unit.

Magnetic flux density measures the strength of a magnetic field. A fridge magnet is about 0.005 T; a strong laboratory magnet is about 0.1 to 1 T; an MRI scanner is 1.5 to 3 T. Small fields are often given in millitesla: 1 mT = 0.001 T.

Because F = BIl, the force is directly proportional to each factor when the other two stay the same: double the current and the force doubles. The graph below was calculated for a 0.050 m length of wire in a 0.20 T field.

01234500.020.040.06current / Aforce / N3.0 A: 0.030 NB = 0.20 T, l = 0.050 m

The gradient of this graph is FI=Bl=0.20×0.050=0.010\frac{F}{I} = Bl = 0.20 \times 0.050 = 0.010 N/A.

Worked example

(Higher tier): basic F = BIl

A wire 0.25 m long carries a current of 4.0 A at right angles to a magnetic field of flux density 0.30 T. Calculate the force on it.

Show solution
  1. Write the equation: F=BIlF = BIl.
  2. Substitute: F=0.30×4.0×0.25F = 0.30 \times 4.0 \times 0.25.
  3. Answer: F=0.30F = 0.30 N.

Worked example

(Higher tier): unit conversions

A wire carries 2.5 A. A 6.0 cm length of it lies at right angles to a field of 40 mT. Calculate the force.

Show solution
  1. Convert to SI units: l=6.0l = 6.0 cm =0.060= 0.060 m; B=40B = 40 mT =0.040= 0.040 T.
  2. F=BIl=0.040×2.5×0.060F = BIl = 0.040 \times 2.5 \times 0.060.
  3. F=0.0060F = 0.0060 N, which is 6.0×10−36.0 \times 10^{-3} N.

Forgetting to convert centimetres or millitesla is the most common way to lose these marks: if you put 6.0 and 40 straight in, your answer is 100 000 times too big.

Worked example

(Higher tier): rearranging

A 12 cm length of wire lies at right angles to a magnetic field. When the current is 3.0 A, the force on it is 0.054 N. Calculate the magnetic flux density.

Show solution
  1. Rearrange: F=BIlF = BIl, so B=FIlB = \frac{F}{Il}.
  2. Convert: l=12l = 12 cm =0.12= 0.12 m.
  3. Substitute: B=0.0543.0×0.12=0.0540.36B = \frac{0.054}{3.0 \times 0.12} = \frac{0.054}{0.36}.
  4. Answer: B=0.15B = 0.15 T.

Similarly I=FBlI = \frac{F}{Bl} and l=FBIl = \frac{F}{BI}.

Worked example

(Higher tier): balancing a wiretop grade

A horizontal copper rod of mass 8.0 g and length 5.0 cm rests across two rails at right angles to a horizontal magnetic field of 0.40 T. What current is needed for the magnetic force on the rod to just balance its weight? (g = 9.8 N/kg)

Show solution
  1. Weight: m=8.0m = 8.0 g =0.0080= 0.0080 kg, so W=mg=0.0080×9.8=0.0784W = mg = 0.0080 \times 9.8 = 0.0784 N.
  2. For the rod to be held up, the magnetic force must equal the weight: F=0.0784F = 0.0784 N, acting upwards.
  3. Rearrange F=BIlF = BIl: I=FBlI = \frac{F}{Bl}.
  4. I=0.07840.40×0.050=0.07840.020=3.92I = \frac{0.0784}{0.40 \times 0.050} = \frac{0.0784}{0.020} = 3.92 A.
  5. Answer: about 3.9 A (2 significant figures, like the data).
  6. Direction: use Fleming's left-hand rule. With the field and the force (up) fixed, the current must flow in the one direction that makes your thumb point up.

Worked example

(Higher tier): changing the factorstop grade

The force on a wire in a magnetic field is 0.12 N. The current is increased from 2.0 A to 5.0 A, and the wire is moved into a weaker field with half the flux density. Calculate the new force.

Show solution
  1. F is proportional to both I and B (l unchanged).
  2. The current is multiplied by 5.02.0=2.5\frac{5.0}{2.0} = 2.5; the flux density is multiplied by 0.5.
  3. New force =0.12×2.5×0.5=0.15= 0.12 \times 2.5 \times 0.5 = 0.15 N.

This ratio method saves time: you don't need B or l at all.