Topic 4.2.4 · Lesson 4 of 4
Exam technique and practice
Worked example
A 6-mark explanation
"Explain why electricity is transmitted through the National Grid at a very high potential difference." (6 marks)
Show solutionHide solution
AQA marks this by levels. A top-level answer (5–6 marks) gives a clear, logically linked explanation: what transformers do, the link between high p.d. and low current for the same power, the link between low current and less heating of the cables, and the result (higher efficiency), with the step-down stage for safety. A middle-level answer (3–4 marks) gives some of these links but misses steps. A low-level answer (1–2 marks) makes isolated points such as "it is more efficient".
Model answer: "The power station generates electricity, which goes to a step-up transformer that increases the potential difference to as much as 400 kV. For the same power, , so if the potential difference is increased the current in the transmission cables is reduced. The cables have resistance, so a current heats them and energy is dissipated to the surroundings. The power wasted is , so reducing the current greatly reduces the energy wasted. Therefore less energy is lost in the cables and the transmission is more efficient. Near homes, step-down transformers reduce the potential difference to about 230 V, which is safer to use."
What lifts it to the top level: every link is present and in order (step up → same power so lower current → less heating of cables → less energy wasted → more efficient), and the step-down transformer is explained.
Exam technique
- Choose the power equation by what you're given: and → ; and → ; and → .
- All of , , and are listed in the specification as equations you must recall.
- For multi-step problems, write down what you know and what you want, and look for the equation that links them. If none links them directly, find an intermediate quantity (often the current or the charge) first.
- National Grid answers need "same power, higher p.d., lower current, less heating, less energy wasted"; a vague "less energy lost" earns little.
- Don't say step-up transformers increase the power; they increase the potential difference and decrease the current, keeping the power (almost) the same.
Common mistakes
- Squaring the resistance, or , in . Fix: square only the current.
- Using minutes or hours in , or kW without converting. Fix: convert to watts and seconds first.
- Saying the National Grid uses high potential difference "to make electricity travel faster" or "further". Fix: it reduces the current and so the energy wasted heating the cables.
- Mixing up the two transformers. Fix: step-up at the power station end, step-down at the consumer end.
- Rounding an intermediate value too early. Fix: keep the full value in your calculator and round only the final answer.
Check yourself
- What is the power of a device with a potential difference of 12 V across it and a current of 2.5 A?
- A current of 0.50 A flows through a 40 Ω resistor. What power is transferred?
- How much energy does a 1.5 kW microwave transfer in 4.0 minutes?
- A 9.0 V battery drives 300 C of charge round a circuit. How much energy does it transfer?
- Describe the energy transfers in an electric drill.
- Which appliance transfers more energy: a 2.0 kW kettle on for 3 minutes, or a 100 W TV on for 1 hour?
- Why do transmission cables waste less energy at high potential difference?
- A 230 V toaster has a power of 920 W. Find the current and its resistance.
- An electric car battery stores J. It is charged at 7.2 kW. How long does a full charge take, in hours?
- A power station delivers 500 kW through cables of resistance 4.0 Ω. Calculate the power wasted when it is transmitted at 10 kV and at 100 kV, and explain the difference.
Show answersHide answers
- W.
- W.
- J.
- J.
- Energy is transferred electrically to the motor, which transfers it to the kinetic store of the drill bit; some is wasted heating the motor and as sound.
- Kettle: J; TV: J. They are equal.
- For the same power, a higher potential difference means a lower current, so less energy is wasted heating the cables ().
- A; Ω (about 58 Ω).
- s hours.
- At 10 kV: A, wasted W; at 100 kV: A, wasted W. Ten times the p.d. gives one tenth of the current, and the power wasted depends on the current squared, so it is 100 times smaller.
Practise this topic
Both are part of Premium.