Topic 7A · Lesson 3 of 4
Investigating rates of reaction
Core practical: rates of reaction
Part (a): marble chips and hydrochloric acid, measuring the gas produced
- Measure 50 cm³ of dilute hydrochloric acid into a conical flask.
- Add a weighed mass of marble chips (for example 5 g of large chips), immediately put in the bung connected to a gas syringe, and start the stopwatch.
- Record the volume of gas every 30 seconds until no more gas is produced.
- Repeat with the same mass of smaller chips, or with a different concentration of acid.
- Plot volume of gas against time for each experiment and compare the gradients at the start.
Variables: the independent variable is the size of the marble pieces (surface area) or the acid concentration; the dependent variable is the volume of gas over time. Control: the mass of marble, the volume of acid, the other factor, and the temperature.
Part (b): sodium thiosulfate and hydrochloric acid, observing a colour change
The sulfur forms as a pale yellow precipitate that makes the mixture cloudy.
- Draw a black cross on a piece of paper and stand a conical flask on it.
- Add 50 cm³ of sodium thiosulfate solution, warmed in a water bath to a set temperature; measure the temperature with a thermometer.
- Add 5 cm³ of dilute hydrochloric acid, swirl, and start the stopwatch.
- Looking down through the flask, stop the clock when the cross can no longer be seen.
- Repeat at other temperatures (for example 20, 30, 40, 50 and 60 °C).
Variables: the independent variable is the temperature (or the thiosulfate concentration); the dependent variable is the time for the cross to disappear. Control: the volumes and concentrations of both solutions, the same flask and cross, and the same person judging the end point.
Sample results for part (b): at 20, 30, 40, 50 and 60 °C, the cross disappeared after 80, 41, 21, 11 and 6 s.
- Calculate the rate as : at 20 °C, s⁻¹; at 30 °C, s⁻¹; at 40 °C, 0.048 s⁻¹; at 50 °C, 0.091 s⁻¹; at 60 °C, 0.17 s⁻¹.
- Each 10 °C rise roughly doubles the rate (80 s → 41 s → 21 s → 11 s), as shown below.
Risks: hydrochloric acid is an irritant, so wear eye protection. The thiosulfate reaction gives off sulfur dioxide, a toxic gas that can trigger asthma attacks, so work in a well-ventilated room, don't heat above about 60 °C, and empty the flask promptly into a sink with plenty of water.
Errors and improvements:
- (a) Some gas escapes before the bung is in, so volumes are too low. Putting the chips in a small tube inside the sealed flask and tipping it over avoids this.
- (a) Chips of the "same size" vary in shape and surface area; using a fixed mass of graded chips helps.
- (b) Judging the moment the cross disappears is subjective: use the same observer, or a light sensor and data logger.
- (b) The mixture cools during the reaction: record the temperature at the start and end and use the mean.
- Repeat each test and calculate a mean.
Practise this topic
Both are part of Premium.