Topic 13A · Lesson 3 of 4
Determining an unknown mass with SHM
Core practical 16: determining an unknown mass
Aim: to determine the value of an unknown mass from the periods (and so the natural frequencies) of oscillation of a spring loaded with known masses.
Apparatus: a spring, a clamp stand with clamp and boss, a mass hanger and slotted masses (100 g each), an object of unknown mass, a stopwatch, and a fiducial marker (a pin or pointer on a second stand).
Method
- Step 1: Hang the spring from the clamp and attach 0.10 kg of masses. Set the fiducial marker level with the equilibrium position.
- Step 2: Pull the masses down a small distance (about 2 cm) and release, so that the oscillation is vertical with no swinging.
- Step 3: Start timing as the mass passes the marker, and time 20 complete oscillations. Repeat and find the mean; divide by 20 to find .
- Step 4: Repeat for masses from 0.10 kg to 0.50 kg.
- Step 5: Replace the masses with the unknown mass and find its period in the same way.
Variables: independent: mass. Dependent: period. Control: the spring, the amplitude (small), and the counting method.
Why time at the equilibrium position? The mass moves fastest there, so the instant it passes the marker is sharply defined. At the extremes it moves slowly, and it is hard to judge exactly when it turns round.
Results processing. From , . A graph of against is a straight line of gradient . Find the unknown mass by reading across from its value of . In practice the line has a small positive intercept, because part of the spring's own mass oscillates too, but the unknown is still read from the line correctly.
Worked example
Processing core practical 16
Times for 20 oscillations with masses of 0.10, 0.20, 0.30, 0.40 and 0.50 kg were 8.36, 11.50, 14.02, 16.06 and 17.97 s. The unknown mass gave 12.90 s.
Show solutionHide solution
- Periods: 0.418, 0.575, 0.701, 0.803 and 0.899 s, so , 0.331, 0.491, 0.645 and 0.807 s², plotted above.
- Gradient s² kg⁻¹, so N m⁻¹.
- Unknown: s and s².
- From the line, , so kg.
- Uncertainty: with a reaction time of about 0.1 s at each end, timing 20 oscillations makes the percentage uncertainty in about , so about 3% in and in the mass.
Sources of error and improvements
- Reaction time: time many oscillations, use a fiducial marker at the equilibrium position, and repeat. A motion sensor and data logger avoid human timing.
- Sideways swinging: release carefully and vertically; restart if the mass swings.
- Large amplitudes can take the spring beyond its limit of proportionality: keep the amplitude small.
- Counting errors: count "zero" at the first pass, not "one".
Risks: masses can fall if the spring overstretches or detaches; clamp the stand firmly (with a counterweight or G-clamp) and keep feet clear.