Topic 3B · Lesson 3 of 4
Measuring the resistivity of a wire
Core practical 2: the resistivity of a material
Aim: to determine the resistivity of a metal, using a wire.
Apparatus: a length of thin wire (such as constantan), metre rule, two crocodile clips (one sliding), low-voltage supply or cell, ammeter, voltmeter, micrometer screw gauge, connecting leads. The diagram shows the arrangement.
Method
- Step 1: Measure the wire's diameter with a micrometer at several points along it, and in two perpendicular directions at each point, and find the mean. Check and correct the micrometer's zero error first.
- Step 2: Tape the wire straight along the metre rule. Attach the fixed clip at the zero mark.
- Step 3: Place the sliding clip at a length (start at 0.100 m), switch on, and record and . Switch off between readings.
- Step 4: Repeat for lengths up to about 0.800 m in equal steps, and repeat each length.
- Step 5: Calculate for each length.
Variables: independent: length . Dependent: resistance (from and ). Control: the same wire (same material and area), and its temperature, kept steady by using a small current and switching off between readings.
Results processing. Rearranging as shows that a graph of against is a straight line through the origin with gradient . So
Any extra resistance from the clips and contacts adds the same amount to every reading. It shows up as an intercept on the axis but does not change the gradient, which is why the graph method is better than a single calculation.
Worked example
Processing core practical 2
A student's constantan wire has a mean diameter of 0.28 mm. The graph above shows the results.
Show solutionHide solution
- Gradient from the triangle: Ω m⁻¹.
- Area: m².
- Ω m.
- The intercept, 0.25 Ω, is the resistance of the clips and contacts, a systematic error that the gradient method removes.
- Uncertainty: if the diameter is mm, its percentage uncertainty is 3.6%, so the area's is 7.1%. This is usually the biggest contribution, which is why the diameter is measured at many points with a micrometer.
Sources of error and improvements
- The wire heats up if the current is large or left on, which increases its resistance: use a low current and switch off between readings.
- The wire may not be uniform: take diameter readings at several places and orientations.
- The clips' contact points are not precisely at the scale marks: use sharp-edged clips or a jockey, and read the position at eye level to avoid parallax.
- A kinked wire has a length different from the scale reading: pull it straight and taut along the rule.
Risks: the wire can get hot; use a low current, and do not touch it while current flows.
Practise this topic
Both are part of Premium.