Skip to main content
Examonaut

Topic 7B · Lesson 3 of 4

Investigating capacitor charge and discharge

Core practical 11: charging and discharging a capacitor

Aim: to display and analyse the p.d. across a capacitor as it charges and discharges through a resistor, and so find the time constant (and, if RR is known, the capacitance).

Apparatus: a capacitor (such as 470 μF), a resistor (such as 47 kΩ), a d.c. supply (6 V), a two-way switch, connecting leads, and a data logger with a voltage sensor (or an oscilloscope; or a voltmeter and stopwatch if RCRC is long).

AB470 μF47 kΩdata logger6.0 V

Method

  1. Step 1: Set up the circuit with the voltage sensor directly across the capacitor.
  2. Step 2: Move the switch to A to charge the capacitor. Start the logger, and record the p.d. as it rises towards 6.0 V.
  3. Step 3: When the capacitor is fully charged (after more than 5RC5RC), move the switch to B and record the p.d. as it discharges, for at least 3RC3RC.
  4. Step 4: Repeat with different resistors or capacitors if investigating how RCRC affects the decay.

Variables: independent: time. Dependent: p.d. across the capacitor. Control: RR, CC and the supply p.d.

Results processing. For the discharge, plot ln⁡V\ln V against tt. A straight line confirms exponential decay; the gradient is −1RC-\dfrac{1}{RC}, so RC=−1gradientRC = -\dfrac{1}{\text{gradient}} and C=RCRC = \dfrac{RC}{R}. A quick check: read the time for VV to fall to 37% of V0V_0, which should equal RCRC, or the time to halve, 0.69RC0.69RC.

−1.0−0.50.00.51.01.52.00204060time / sln (V / V)50 s−2.259

Worked example

Processing core practical 11

The discharge p.d. readings every 10 s are 6.00, 3.80, 2.44, 1.53, 0.99, 0.62 and 0.40 V, plotted as ln⁡V\ln V above. The resistor is 47.0 kΩ.

Show solution
  1. Gradient =−0.695−1.56455−5=−2.25950=−0.0452= \dfrac{-0.695 - 1.564}{55 - 5} = \dfrac{-2.259}{50} = -0.0452 s⁻¹.
  2. RC=10.0452=22.1RC = \dfrac{1}{0.0452} = 22.1 s.
  3. C=22.147.0×103=4.70×10−4C = \dfrac{22.1}{47.0 \times 10^3} = 4.70 \times 10^{-4} F = 470 μF, matching the label.
  4. Check: VV should be 0.37×6.00=2.220.37 \times 6.00 = 2.22 V after 22 s; the data give 2.44 V at 20 s, consistent.

Sources of error and improvements

  • Capacitor tolerances are often ±10% or ±20%, so the labelled value may differ from the true one: the experiment measures the true value.
  • If timing by hand with a voltmeter, use a large RCRC (a minute or more) so that reaction time is small compared with the time measured; a data logger removes this problem.
  • Leakage through the dielectric and the meter's own resistance (in parallel with RR) speed up the discharge: use a high-resistance voltmeter or logger.
  • Electrolytic capacitors must be connected the right way round.

Risks: large capacitors charged to high p.d. can deliver a dangerous shock and store energy even when disconnected; use low voltages, observe polarity, and discharge capacitors through a resistor before handling.

Practise this topic

Both are part of Premium.