Topic 16C · Lesson 2 of 3
Core practical 14: finding an activation energy
Core Practical 14: finding an activation energy
Aim: to find the activation energy of a reaction using a clock reaction at different temperatures. A common choice is bromide ions with bromate(V) ions in acid, , with a small fixed amount of phenol and some methyl red: the bromine formed first reacts with the phenol, and once the phenol is used up the next bromine bleaches the methyl red, so the time is for a fixed amount of reaction. Any clock reaction (for example peroxodisulfate with iodide, thiosulfate and starch) works the same way.
Apparatus: boiling tubes, measuring cylinders or burettes, a water bath (or beaker of water heated on a hot plate), thermometer, stopwatch, and the indicator for your clock reaction (methyl red, or starch for an iodine clock). The diagram shows the set-up.
Method
- Step 1: Measure the two reacting solutions into separate boiling tubes (for example bromide, bromate(V), phenol and methyl red in one and the acid in the other; or, for an iodine clock, peroxodisulfate in one and iodide, thiosulfate and starch in the other).
- Step 2: Stand both tubes in the water bath until they reach the bath temperature (check with the thermometer).
- Step 3: Mix them, start the stopwatch, and record the time for the colour change (the indicator is bleached, or the blue-black colour appears). Record the actual temperature of the mixture.
- Step 4: Repeat at four or more other temperatures between about 20 °C and 60 °C, using exactly the same volumes and concentrations.
Variables: independent, temperature; dependent, time for the colour change; control, concentrations and volumes of all solutions.
Risks: phenol is toxic and corrosive, and bromine is toxic, so avoid skin contact and work in a well-ventilated room; potassium peroxodisulfate (if used) is an oxidiser and irritant; hot water can scald. Wear eye protection.
Sample results: 293 K, 120 s; 303 K, 59 s; 313 K, 31 s; 323 K, 16.5 s; 333 K, 9.2 s. The Arrhenius plot of these results is below.
Worked example
Activation energy from the graphtop grade
Use the line of best fit in the plot above to find .
Show solutionHide solution
- Choose two points on the line far apart: at , ; at , .
- The values are , so convert to : and K⁻¹.
- Gradient K.
- J mol⁻¹ kJ mol⁻¹.
The common slips are forgetting the factor of 1000 on the -axis, and leaving the answer in J mol⁻¹ with the wrong number of figures.
Errors and improvements: the temperature of the mixture can change during the reaction, especially far from room temperature (record the temperature at the start and end and use the mean, or keep the tube in the bath); judging the moment the colour appears (use a white background; repeat and average); at high temperatures times are short, so reaction-time error in the stopwatch is a larger percentage (use more dilute solutions to give longer times).
Worked example
Two temperatures onlytop grade
The rate of a reaction doubles when the temperature rises from 298 K to 308 K, with all concentrations kept the same. Estimate .
Show solutionHide solution
- Write the logarithmic form at both temperatures and subtract: , so .
- , so .
- K⁻¹.
- J mol⁻¹ kJ mol⁻¹.
This is the origin of the rule of thumb that a 10 K rise doubles the rate: it is true for activation energies of about 50 kJ mol⁻¹ near room temperature.
Catalysts and the Arrhenius equation
A catalyst provides a route with a lower activation energy. In , a smaller makes the exponent less negative, so is larger at every temperature. On an Arrhenius plot the catalysed line is less steep (smaller ) and lies above the uncatalysed line, as the sketch shows. A catalyst does not change the temperature or the concentrations; it changes .