Skip to main content
Examonaut

Topic 16A · Lesson 3 of 4

Following rates: iodine–propanone and clock reactions

Ways to follow a reaction

Choose a property that changes as the reaction proceeds and can be measured without disturbing it:

  • Colorimetry: if a reactant or product is coloured (iodine, bromine, manganate(VII)), measure absorbance with a colorimeter and convert to concentration with a calibration graph.
  • Gas volume or mass loss: when a gas is produced.
  • pH or conductivity: when the number of H⁺ or other ions changes.
  • Sampling and quenching: remove samples at intervals and stop the reaction in each, by cooling rapidly, diluting, or removing a catalyst, then analyse by titration.
  • Clock reactions: measure the time tt for a fixed small amount of product to form, which shows as a sudden colour change. Since the same small amount forms each time, the initial rate is proportional to 1t\dfrac{1}{t}.

Core Practical 13: iodine and propanone

In acid, iodine reacts with propanone:

CH3COCH3(aq)+I2(aq)→H+CH3COCH2I(aq)+HI(aq)\text{CH}_3\text{COCH}_3\text{(aq)} + \text{I}_2\text{(aq)} \xrightarrow{\text{H}^+} \text{CH}_3\text{COCH}_2\text{I(aq)} + \text{HI(aq)}

Aim: to find the order with respect to iodine by following [I₂] over time.

Method: propanone and acid are in large excess, so only [I₂] changes significantly. The flow chart shows the procedure.

mix propanone,acid and iodine;start timerevery few min:pipette 10 cm³samplerun intoNaHCO₃(aq):reaction stopstitrate I₂ withNa₂S₂O₃, starchnear endplot [I₂]against time
  1. Mix measured volumes of propanone and sulfuric acid; add the iodine solution and start the timer.
  2. At regular intervals, pipette a 10.0 cm³ sample into a flask of sodium hydrogencarbonate solution. This neutralises the acid catalyst, which quenches (stops) the reaction.
  3. Titrate the iodine remaining with standard sodium thiosulfate, adding starch near the end point.
  4. Calculate [I₂] at each time and plot [I₂] against time.

Results: the graph is a straight line, so the rate is constant and the reaction is zero order with respect to iodine.

01020300.00000.00050.00100.00150.00200.0025time / min[I₂] / mol dm⁻³

Sample processing: the gradient is 0.00050−0.0020025−0=−6.0×10−5\dfrac{0.00050 - 0.00200}{25 - 0} = -6.0 \times 10^{-5} mol dm⁻³ min⁻¹, so the rate is 6.0×10−56.0 \times 10^{-5} mol dm⁻³ min⁻¹ =1.0×10−6= 1.0 \times 10^{-6} mol dm⁻³ s⁻¹. Repeating with different concentrations of propanone and acid shows the reaction is first order in each, so rate =k[CH3COCH3][H+]= k[\text{CH}_3\text{COCH}_3][\text{H}^+]. Note that H⁺, a catalyst, appears in the rate equation, while iodine, a reactant, does not.

Risks: propanone is highly flammable; iodine solution stains and irritates; sulfuric acid is an irritant. Wear eye protection.

Errors and improvements: the timing of quenching (record the time when half the sample has entered the hydrogencarbonate); temperature changes (use a water bath); the end point (add starch only near it).

Core Practical 13: a clock reaction

In an iodine clock, hydrogen peroxide (or peroxodisulfate) oxidises iodide ions in the presence of a small fixed amount of sodium thiosulfate and starch. The thiosulfate immediately turns any iodine back into iodide, until it is all used up; then iodine builds up and the starch suddenly turns blue-black. The time tt is when a fixed amount of iodine has formed.

  1. Keep the total volume constant (add water) and vary only one concentration, for example [I⁻].
  2. Record tt for each run, in a water bath at constant temperature.
  3. Plot 1t\dfrac{1}{t} (proportional to initial rate) against concentration: a straight line through the origin shows first order.

For example, if doubling [I⁻] halves the time from 80 s to 40 s, then 1t\dfrac{1}{t} doubles, and the reaction is first order with respect to iodide.

Practise this topic

Both are part of Premium.