Topic 16A · Lesson 3 of 4
Following rates: iodine–propanone and clock reactions
Ways to follow a reaction
Choose a property that changes as the reaction proceeds and can be measured without disturbing it:
- Colorimetry: if a reactant or product is coloured (iodine, bromine, manganate(VII)), measure absorbance with a colorimeter and convert to concentration with a calibration graph.
- Gas volume or mass loss: when a gas is produced.
- pH or conductivity: when the number of H⁺ or other ions changes.
- Sampling and quenching: remove samples at intervals and stop the reaction in each, by cooling rapidly, diluting, or removing a catalyst, then analyse by titration.
- Clock reactions: measure the time for a fixed small amount of product to form, which shows as a sudden colour change. Since the same small amount forms each time, the initial rate is proportional to .
Core Practical 13: iodine and propanone
In acid, iodine reacts with propanone:
Aim: to find the order with respect to iodine by following [I₂] over time.
Method: propanone and acid are in large excess, so only [I₂] changes significantly. The flow chart shows the procedure.
- Mix measured volumes of propanone and sulfuric acid; add the iodine solution and start the timer.
- At regular intervals, pipette a 10.0 cm³ sample into a flask of sodium hydrogencarbonate solution. This neutralises the acid catalyst, which quenches (stops) the reaction.
- Titrate the iodine remaining with standard sodium thiosulfate, adding starch near the end point.
- Calculate [I₂] at each time and plot [I₂] against time.
Results: the graph is a straight line, so the rate is constant and the reaction is zero order with respect to iodine.
Sample processing: the gradient is mol dm⁻³ min⁻¹, so the rate is mol dm⁻³ min⁻¹ mol dm⁻³ s⁻¹. Repeating with different concentrations of propanone and acid shows the reaction is first order in each, so rate . Note that H⁺, a catalyst, appears in the rate equation, while iodine, a reactant, does not.
Risks: propanone is highly flammable; iodine solution stains and irritates; sulfuric acid is an irritant. Wear eye protection.
Errors and improvements: the timing of quenching (record the time when half the sample has entered the hydrogencarbonate); temperature changes (use a water bath); the end point (add starch only near it).
Core Practical 13: a clock reaction
In an iodine clock, hydrogen peroxide (or peroxodisulfate) oxidises iodide ions in the presence of a small fixed amount of sodium thiosulfate and starch. The thiosulfate immediately turns any iodine back into iodide, until it is all used up; then iodine builds up and the starch suddenly turns blue-black. The time is when a fixed amount of iodine has formed.
- Keep the total volume constant (add water) and vary only one concentration, for example [I⁻].
- Record for each run, in a water bath at constant temperature.
- Plot (proportional to initial rate) against concentration: a straight line through the origin shows first order.
For example, if doubling [I⁻] halves the time from 80 s to 40 s, then doubles, and the reaction is first order with respect to iodide.
Practise this topic
Both are part of Premium.