Skip to main content
Examonaut

Topic 14A · Lesson 1 of 4

Half-cells, the SHE and cell e.m.f.

Redox reactions with the electrons in a wire

Put a strip of zinc into copper(II) sulfate solution and it becomes coated with copper while the blue colour fades. Zinc atoms give electrons to copper(II) ions:

Zn(s)+Cu2+(aq)→Zn2+(aq)+Cu(s)\text{Zn(s)} + \text{Cu}^{2+}\text{(aq)} \rightarrow \text{Zn}^{2+}\text{(aq)} + \text{Cu(s)}

Remember the definitions: oxidation is loss of electrons (oxidation number goes up); reduction is gain of electrons (oxidation number goes down). Split into half-equations:

  • Oxidation: Zn→Zn2++2e−\text{Zn} \rightarrow \text{Zn}^{2+} + 2\text{e}^-
  • Reduction: Cu2++2e−→Cu\text{Cu}^{2+} + 2\text{e}^- \rightarrow \text{Cu}

In the beaker the electrons pass directly and the energy is just released as heat. Now separate the two halves. Put zinc in a solution of Zn²⁺ ions in one beaker, and copper in Cu²⁺ ions in another. Each beaker is a half-cell. Join the metals with a wire and the solutions with a salt bridge, as the diagram shows. Electrons now flow through the wire from zinc to copper, and a voltmeter shows 1.10 V.

Zn²⁺(aq)1.00 mol dm⁻³Cu²⁺(aq)1.00 mol dm⁻³Zn (−)Cu (+)salt bridge (KNO₃)Ve⁻1.10 V
  • The salt bridge is usually filter paper soaked in saturated potassium nitrate solution. It completes the circuit by letting ions move between the solutions, keeping each one electrically neutral, without the two solutions mixing. KNO₃ is chosen because its ions do not react with the solutions or form precipitates (chlorides would precipitate with Ag⁺, for instance).
  • The voltmeter must have a very high resistance, so almost no current flows. Then the reading is the maximum potential difference, the e.m.f. (electromotive force) of the cell, and the concentrations do not change during the measurement.

Why each half-cell has a potential

In the zinc half-cell an equilibrium is set up at the metal surface:

Zn2+(aq)+2e−⇌Zn(s)\text{Zn}^{2+}\text{(aq)} + 2\text{e}^- \rightleftharpoons \text{Zn(s)}

Zinc is a reactive metal, so the equilibrium lies to the left: some zinc atoms leave as ions, leaving their electrons behind on the metal, which becomes negatively charged. Copper is much less reactive; its equilibrium lies further to the right, so its surface is much less negative. That difference in "electron pressure" is what drives electrons from zinc to copper. You cannot measure the potential of one half-cell on its own, because any measurement needs two connections. So every half-cell is compared with one agreed reference.

The standard hydrogen electrode

The reference is the standard hydrogen electrode (SHE), shown on the left of the diagram below. Hydrogen gas at 100 kPa bubbles over a platinum electrode dipping into a solution of H⁺ ions at 1.00 mol dm⁻³, at 298 K. The platinum is inert: it does not react, but it conducts electrons and provides a surface for the equilibrium

2H+(aq)+2e−⇌H2(g)2\text{H}^+\text{(aq)} + 2\text{e}^- \rightleftharpoons \text{H}_2\text{(g)}

By definition its potential is exactly 0.00 V.

H₂(g), 100 kPa1.00 mol dm⁻³ H⁺(aq)298 KPtFe³⁺(aq) and Fe²⁺(aq)both 1.00 mol dm⁻³PtV+0.77 V

The standard electrode potential, E°, of a half-cell is the e.m.f. of a cell made from that half-cell and a standard hydrogen electrode, under standard conditions: 298 K, 100 kPa for gases and 1.00 mol dm⁻³ for all ions in solution. The sign is the charge of the half-cell relative to the SHE. The diagram shows the Fe³⁺/Fe²⁺ half-cell reading +0.77 V.

There are three kinds of half-cell:

  1. Metal and its ions: the metal itself is the electrode (Zn in Zn²⁺).
  2. Non-metal and its ions: a gas or solution with a platinum electrode (Cl₂ bubbling over Pt in Cl⁻ ions).
  3. Two ions of the same element in different oxidation states, mixed at equal concentrations with a platinum electrode (Fe³⁺ and Fe²⁺).

Half-equations are always written as reductions, with the electrons on the left, and the E° refers to that direction.

Cell diagrams

A cell can be written in shorthand. For the zinc–copper cell:

Zn(s) | Zn²⁺(aq) || Cu²⁺(aq) | Cu(s)

  • A single vertical line shows a boundary between phases (metal and solution).
  • The double line in the middle is the salt bridge (exam papers often print it as two dashed lines).
  • By convention the negative electrode, where oxidation happens, goes on the left, written with the reduced form at the outside: metal first.
  • Where platinum is used, it goes on the outside and both species in the solution are separated by a comma: for example Pt(s) | H₂(g) | 2H⁺(aq) || Fe³⁺(aq), Fe²⁺(aq) | Pt(s).

Calculating the cell e.m.f.

Ecell∘=Eright∘−Eleft∘=E∘(positive electrode)−E∘(negative electrode)E^\circ_{\text{cell}} = E^\circ_{\text{right}} - E^\circ_{\text{left}} = E^\circ(\text{positive electrode}) - E^\circ(\text{negative electrode})

The half-cell with the more positive E° is the positive electrode, where reduction happens. The one with the more negative E° is the negative electrode, where oxidation happens. Electrons flow in the wire from negative to positive. For the zinc–copper cell, Ecell∘=+0.34−(−0.76)=+1.10E^\circ_{\text{cell}} = +0.34 - (-0.76) = +1.10 V.

Try it: pick any two half-cells to see the e.m.f., which electrode is positive, the overall equation and the cell diagram.

Try it: simulation

Electrochemical cells

Loading the simulation…

Practise this topic

Both are part of Premium.