Skip to main content
Examonaut

Topic 5B · Lesson 4 of 5

Measuring respiration with a respirometer

Core practical 9: measuring the rate of respiration with a respirometer

Aim. To investigate the effect of a factor, such as temperature, on the rate of aerobic respiration of small organisms (germinating seeds, or invertebrates such as woodlice or maggots).

Apparatus. A respirometer (diagram below): two boiling tubes connected by a capillary U-tube containing coloured fluid, with a scale; soda lime (which absorbs CO₂); gauze platforms; glass beads; a syringe and three-way tap to reset the fluid; a water bath; a thermometer; a stopwatch.

glass beads (control)germinating seedsscalefluid movestowards seedscoloured fluid in a capillary U-tubesoda lime under gauze in both

Method.

  1. Step 1: Put soda lime in the bottom of each tube and a gauze platform above it (so organisms do not touch the soda lime, which is caustic).
  2. Step 2: Put a known mass of germinating seeds in one tube, and glass beads of the same volume in the other (the control tube). The control compensates for any changes in temperature and atmospheric pressure, which would affect both tubes equally.
  3. Step 3: Connect the tubes to the U-tube and stand them in a water bath at the chosen temperature. Leave for 10 minutes to equilibrate, with the taps open.
  4. Step 4: Close the taps and start the stopwatch. As the seeds respire, they take in O₂ and give out CO₂, but the soda lime absorbs the CO₂. So the volume of gas in the seed tube falls, the pressure falls, and the fluid in the U-tube moves towards the seeds.
  5. Step 5: Record the distance the fluid moves in a set time. Reset using the syringe, and repeat.
  6. Step 6: Repeat at other temperatures.
  7. Step 7: Calculate the volume of oxygen used: volume =πr2×= \pi r^2 \times distance moved, where rr is the radius of the capillary. Divide by time and mass for the rate.

Variables. Independent: temperature. Dependent: volume of O₂ used per unit time per unit mass. Controlled: mass and type of organisms, mass of soda lime, volume of air, time allowed to equilibrate.

Safe and ethical use of organisms. Soda lime is corrosive: wear eye protection and keep it away from organisms with a gauze barrier. If using animals, handle them gently, keep them for the shortest time possible, use temperatures they would meet naturally (not extremes that cause suffering), and return them to their habitat afterwards. Seeds avoid most ethical problems.

Worked example

Calculating the rate of oxygen uptake

The fluid moved 36 mm in 10 minutes in a capillary of radius 0.5 mm. The seeds had a mass of 4.0 g. Calculate the rate of oxygen uptake.

Show solution
  1. Volume of oxygen used =πr2l=3.14×0.52×36=28.3= \pi r^2 l = 3.14 \times 0.5^2 \times 36 = 28.3 mm³.
  2. Rate per minute: 28.3÷10=2.8328.3 \div 10 = 2.83 mm³ min⁻¹.
  3. Per gram: 2.83÷4.0=0.712.83 \div 4.0 = 0.71 mm³ g⁻¹ min⁻¹.

Measuring RQ. Repeat with water instead of soda lime, so CO₂ is not absorbed. The fluid now moves by (O₂ used − CO₂ produced). If the fluid moves 36 mm with soda lime and 2 mm with water, CO₂ produced corresponds to 36−2=3436 - 2 = 34 mm, so RQ =34÷36=0.94= 34 \div 36 = 0.94.

Errors and improvements. Small temperature changes have a large effect on gas volume, so use a water bath and the control tube. Leaks make readings too small, so check all joints. Seeds of different ages respire at different rates, so use seeds from the same batch and the same mass. Repeat and calculate means.

Practise this topic

Both are part of Premium.